2025, Vol. 12, No. 4. - go to content...
Permanent address of this page - https://t-s.today/en/08sats425.html
Метаданные этой статьи так же доступны на русском языке
DOI: 10.15862/08SATS425 (https://doi.org/10.15862/08SATS425)
Full article in PDF format (file size: 1.1 MB)
For citation:
Shmelev V.A., Rostovykh G.N., Vasilyev A.I., Ryumin M.G. Study of standardized parameters of chemical anchors at transport facilities. Russian Journal of Transport Engineering. 2025; 12(3). Available at: https://t-s.today/PDF/08SATS425.pdf (in Russian). DOI: 10.15862/08SATS425
Study of standardized parameters of chemical anchors at transport facilities
Shmelev Vasily Alekseevich
Research Institute of Bridges and Defectoscopy, Saint Petersburg, Russia
E-mail: niim-shmelev@mail.ru
RSCI: https://elibrary.ru/author_profile.asp?id=697056
Rostovykh Gregory Nikolaevich
Research Institute of Bridges and Defectoscopy, Saint Petersburg, Russia
E-mail: g@rostovykh.com
ORCID: https://orcid.org/0000-0001-5001-4273
RSCI: https://elibrary.ru/author_profile.asp?id=1314524
Vasilyev Alexander Ilyich
Moscow Automobile and Road Construction State Technical University (MADI), Moscow, Russia
E-mail: 655178@mail.ru
RSCI: https://elibrary.ru/author_profile.asp?id=285715
Ryumin Maksim Gennadievich
Russian University of Transport (MIIT), Moscow, Russia
E-mail: averti@bk.ru
ORCID: https://orcid.org/0009-0005-2074-0537
Abstract. In 2024, the Research Institute of Bridges, on the instructions of the Federal Autonomous Institution Federal Center for Normation, Standardization and Technical Assessment of Conformity in Construction (FAU «FCS») of the Ministry of Construction of the Russian Federation, within the framework of the state program of the Russian Federation «Development of Industry and Increasing its Competitiveness» (RF Government Resolution of April 15, 2014 N 328), carried out R&D on the topic: «Experimental studies of domestically produced anchor chemical fasteners for use at transport facilities (bridges, road and railway tunnels, etc.), including under high loads».
The aim of the study was to obtain standardized parameters when using domestically produced chemical anchor fasteners. The study included 22 series of tests divided into three groups: to determine the minimum edge and center-to-center distances, permissible pulling and shearing loads; to check the susceptibility of anchors to installation and operating conditions; a group of full-scale studies to determine the actual bearing capacity of fasteners in real operating conditions. After statistical processing of the test results, additions and recommendations for changes in the provisions of regulatory documents were formulated. Also, based on the test results, it was concluded that domestic chemical anchors are not inferior to European-made anchors, and their use will allow achieving significant profits.
Keywords: anchor fastening; anchor; chemical anchor; adhesive anchor; injection anchor; working conditions coefficient; mechanical characteristics; endurance tests; domestic manufacturer